Variable Frequency Drives
Fields of application:
Replacement of variators
Pumps and fans control
Food processing machines
Transport lines and conveyers
Elevating transport equipment (lifts and cranes)
Wood processing machines
Textile machines
Extruders
Industrial washing machines

ELDI – M
ELDI – M variable frequency drives are designed for speed control of standard three phase AC motors with single phase power supply and
power range 0,37 kW to 0,75 kW
| Parameter: | ELDI - M: | ||||
|---|---|---|---|---|---|
| Motor power | 0,37kW 0,55kW 0.75kW |
||||
| Supply voltage and frequency | |||||
| Rated output voltage | 200 ÷ 230V 3~ (corresponds to the input voltage) | ||||
| Rated output current | 2.2A 3.0A 4.3A |
||||
| Motor control methods | Version C | ||||
| Version C2 | |||||
| Degree of protection | |||||
| Output frequency | |||||
| Overload current capacity | |||||
| Acceleration / Deceleration time | |||||
| Frequency control | With keypad | ||||
| External signal | |||||
| Start Stop Reverse | With keypad | button “Stop” |
|||
| External signal | |||||
| Inputs | |||||
| Relay outputs | |||||
| Programmable analog outputs | |||||
| Protections | Under voltage Over voltage Overheat Ground fault Overload Eeprom error |
||||
| Fan control | |||||
| Weight | |||||
| Options | |||||
ELDI – А
ELDI – A variable frequency drives are designed for speed control of standard three phase AC motors with single phase power supply and
power range 0,55 kW to 2,2 kW
| Parameter: | ELDI - A: | ||||||
|---|---|---|---|---|---|---|---|
| Motor power | 0.55kW 0.75kW 1.1kW 1.5kW 2.2kW |
||||||
| Supply voltage and frequency | |||||||
| Rated output voltage | |||||||
| Rated output current | 3.0A 4.3A 5.9A 7.1A 10.1A |
||||||
Motor control methods | Version C | flux vector control |
|||||
| Version C2 | flux vector control with feedback from tacho or encoder |
||||||
| Degree of protection | |||||||
| Output frequency | |||||||
| Overload current capacity | |||||||
| Acceleration / Deceleration time | |||||||
Frequency control | With keypad | ||||||
| External signal | |||||||
potentiometer 2 ÷ 10kΩ |
|||||||
Start Stop Reverse | With keypad | button “Stop” |
|||||
| External signal | |||||||
| Inputs | Analog 4 ÷ 20mA Two analog 0 ÷ 10V Digital - “F/R” |
||||||
| Relay outputs | |||||||
| Programmable analog outputs | |||||||
| Protections | Undervoltage Ground fault Overload Eeprom error Overvoltage Overheat |
||||||
| Fan control | |||||||
| Weight | 1.5kg 1.5kg 1.5kg 2.2kg 2.2kg |
||||||
| Options | RS 232 (with additional TTL-RS converter) Remote control - with LCS display / without display (reversible / nonreversible) with LED display and keyboard by RS port |
||||||


ELDI – B
ELDI – B variable frequency drives are designed for speed control of standard three phase AC motors with three phase power supply and
power range 0,55 kW to 5,5 kW
| Parameter: | ELDI - B: | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Motor power | 0.55kW 0.75kW 1.1kW 1.5kW 2.2kW 3.0kW 4.0kW 5.5kW |
|||||||||
| Supply voltage and frequency | ||||||||||
| Rated output voltage | ||||||||||
| Rated output current | 2.3A 3.2A 4.2A 6.0A 7.6A 10.2A 12.5A |
|||||||||
| Motor control methods | Version C | flux vector control |
||||||||
| Version C2 | flux vector control with feedback from tacho or encoder |
|||||||||
| Degree of protection | ||||||||||
| Output frequency | ||||||||||
| Overload current capacity | ||||||||||
| Acceleration / Deceleration time | ||||||||||
| Frequency control | With keypad | |||||||||
| External signal | 4 ÷ 20mA (input impedance 250Ω) potentiometer 2 ÷ 10kΩ |
|||||||||
| Start Stop Reverse | With keypad | button “Stop” Reverse - through “dtS” - F/R |
||||||||
| External signal | Reverse - digital input “F/R” |
|||||||||
| Inputs | Analog 4 ÷ 20mA Two analog 0 ÷ 10V; Digital - “F/R” |
|||||||||
| Relay outputs | ||||||||||
| Programmable analog outputs | ||||||||||
| Protections | Under voltage Over voltage Overheat Ground fault Overload Eeprom error |
|||||||||
| Fan control | ||||||||||
| Weight | 1,5kg 1,5kg 2,2kg 2,2kg 2,6kg 3,4kg 3,4kg |
|||||||||
| Options | RS 232 (with additional TTL-RS converter) Remote control - with LCS display / without display (reversible / nonreversible) with LED display and keyboard by RS port |
|||||||||
ELDI – DF
ELDI – DF variable frequency drives are designed for speed control of standard three phase AC motors with three phase power supply and
power range 7,5 kW to 11,0 kW
| Parameter: | ELDI - DF: | ||||
|---|---|---|---|---|---|
| Motor power | 7.5kW 11kW |
||||
| Supply voltage and frequency | 50/60Hz ±5% |
||||
| Rated output voltage | 380 ÷ 400V 3~ (corresponds to the input voltage) | ||||
| Rated output current | 16A 22A |
||||
| Motor control methods | Version C | flux vector control |
|||
| Version C2 | |||||
| Degree of protection | |||||
| Output frequency | |||||
| Overload current capacity | |||||
| Acceleration / Deceleration time | |||||
Frequency control | With keypad | ||||
| External signal | |||||
| Start Stop Reverse | With keypad | button “Stop” |
|||
| External signal | |||||
| Inputs | Analog 4 ÷ 20mA Two analog 0 ÷ 10V Digital - “F/R” |
||||
| Relay outputs | (ready; speed reference reached) |
||||
| Programmable analog outputs | (output frequency / motor current) |
||||
| Protections | Undervoltage Overvoltage Overheat Ground fault Overload Eeprom error |
||||
| Fan control | Detect heatsink temperature to start or stop the cooling fan | ||||
| Weight | |||||
| Options | (with additional TTL-RS converter) Remote control - with LCS display / without display (reversible / nonreversible) with LED display and keyboard by RS port |
||||


ELDI / V – A
ELDI/V – A variable frequency drives are designed for vector control of standard three phase AC motors with single phase power supply and
power range 0,55 kW to 2,2 kW
| Parameter: | ELDI / V - A: | |||
|---|---|---|---|---|
| Motor power | 1.1kW 1.5kW 2.2kW |
|||
| Supply voltage and frequency | ||||
| Rated output voltage | ||||
| Rated output current | 5.9A 7.1A 10.1A |
|||
| Motor control methods | Open loop U/F Closed Loop Vector control Sensorless Vector control |
|||
| Speed control range | 1:1000 (Closed Loop Vector control) |
|||
| Degree of protection | ||||
| Output frequency | ||||
| Output current overload capacity | ||||
| Acceleration / Deceleration time | ||||
| Controls | through external Analog signal by external potentiometer using Pulse Train input Operator Keypad settings |
|||
| Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
||
| Digital inputs | ||||
| Serial interface | ||||
| Inputs | Analog | |||
| Digital | ||||
| Outputs | Analog | |||
| Digital | ||||
| Relays | ||||
| Compatible encoders and feedback interfaces | ||||
| Protections | Under Voltage Over Voltage Over Heat Earth Fault Over Load (l2t) PG Fail, Disconnected Output Phase |
|||
| Fieldbus Connectivity | RS 232 (optional) |
|||
| Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
|||
ELDI / V – B
ELDI/V – B variable frequency drives are designed for vector control of standard three phase AC motors with three phase power supply and
power range 0,55 kW to 5,5 kW
| Parameter: | ELDI / V - B: | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Motor power | 0.5kW 0.7kW 1.1kW 1.5kW 2.2kW 3kW 4kW 5kW | ||||||||
| Supply voltage and frequency | |||||||||
| Rated output voltage | |||||||||
| Rated output current | 2.0A 2.3A 3.2A 4.2A 6.0A 7.6A 10.0A12.0A |
||||||||
| Motor control methods | Open loop U/F. Closed Loop Vector control. Sensorless Vector control |
||||||||
| Speed control range | 1:1000 (Closed Loop Vector control) |
||||||||
| Degree of protection | |||||||||
| Output frequency | |||||||||
| Output current overload capacity | |||||||||
| Acceleration / Deceleration time | |||||||||
| Controls | through external Analog signal. by external potentiometer. using Pulse Train input Operator Keypad settings through Modbus RTU (RS485) |
||||||||
| Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
|||||||
| Digital inputs | |||||||||
| Serial interface | |||||||||
| Inputs | Analog | 0 ÷ 10V or 4 ÷ 20mA |
|||||||
| Digital | |||||||||
| Outputs | Analog | ||||||||
| Digital | |||||||||
| Relays | |||||||||
| Compatible encoders and feedback interfaces | |||||||||
| Protections | Over Voltage, Over Heat Earth Fault, Over Load (l2t) PG Fail Disconnected Output Phase |
||||||||
| Fieldbus Connectivity | RS 232 (optional) |
||||||||
| Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
||||||||


ELDI / V – DF
| Parameter: | ELDI / V - DF: | ||
|---|---|---|---|
| Motor power | 11.0kW |
||
| Supply voltage and frequency | |||
| Rated output voltage | |||
| Rated output current | 22A |
||
| Motor control methods | |||
| Speed control range | 1:1000 (Closed Loop Vector control) |
||
| Degree of protection | |||
| Output frequency | |||
| Output current overload capacity | |||
| Acceleration / Deceleration time | |||
| Controls | through external Analog signal by external potentiometer; using Pulse Train input Operator Keypad settings through Modbus RTU (RS485) |
||
| Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
|
| Digital inputs | |||
| Serial interface | |||
| Inputs | Analog | 0 ÷ 10V or 4 ÷ 20mA |
|
| Digital | |||
| Outputs | Analog | ||
| Digital | |||
| Relays | |||
| Compatible encoders and feedback interfaces | |||
| Protections | Under Voltage Over Voltage Over Heat Earth Fault Over Load (l2t) PG Fail Disconnected Output Phase |
||
| Fieldbus Connectivity | Modbus RTU RS 232 (optional) |
||
| Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
||
ELDI / V – D
ELDI/V – D variable frequency drives are designed for vector control of standard three phase AC motors with three phase power supply and
power range 15,0 kW to 75,0 kW
| Parameter: | ELDI / V - D: | |||||||
|---|---|---|---|---|---|---|---|---|
| Motor power | 15kW 18kW 22kW 30kW 37kW 45kW 55kW 75kW | |||||||
| Supply voltage and frequency | ||||||||
| Rated output voltage | ||||||||
| Rated output current | 29A 36A 42A 62A 72A 85A 105A 138A |
|||||||
| Motor control methods | Open loop U/F. Closed Loop Vector control. Sensorless Vector control |
|||||||
| Speed control range | ||||||||
| Degree of protection | ||||||||
| Output frequency | ||||||||
| Output current overload capacity | ||||||||
| Acceleration / Deceleration time | ||||||||
| Controls | through external Analog signal. by external potentiometer. using Pulse Train input Operator Keypad settings through Modbus RTU (RS485) |
|||||||
| Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
||||||
| Digital inputs | ||||||||
| Serial interface | ||||||||
| Inputs | Analog | 0 ÷ 10V or 4 ÷ 20mA |
||||||
| Digital | ||||||||
| Outputs | Analog | |||||||
| Digital | ||||||||
| Relays | ||||||||
| Compatible encoders and feedback interfaces | ||||||||
| Protections | Over Voltage, Over Heat Earth Fault, Over Load (l2t) PG Fail, Disconnected Output Phase |
|||||||
| Fieldbus Connectivity | RS 232 (optional) |
|||||||
| Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
|||||||