Variable Frequency Drives
Fields of application:
Replacement of variators
Pumps and fans control
Food processing machines
Transport lines and conveyers
Elevating transport equipment (lifts and cranes)
Wood processing machines
Textile machines
Extruders
Industrial washing machines

ELDI – M
ELDI – M variable frequency drives are designed for speed control of standard three phase AC motors with single phase power supply and
power range 0,37 kW to 0,75 kW
Parameter: | ELDI - M: | ||||
---|---|---|---|---|---|
Motor power | 0,37kW 0,55kW 0.75kW |
||||
Supply voltage and frequency | |||||
Rated output voltage | 200 ÷ 230V 3~ (corresponds to the input voltage) | ||||
Rated output current | 2.2A 3.0A 4.3A |
||||
Motor control methods | Version C | ||||
Version C2 | |||||
Degree of protection | |||||
Output frequency | |||||
Overload current capacity | |||||
Acceleration / Deceleration time | |||||
Frequency control | With keypad | ||||
External signal | |||||
Start Stop Reverse | With keypad | button “Stop” |
|||
External signal | |||||
Inputs | |||||
Relay outputs | |||||
Programmable analog outputs | |||||
Protections | Under voltage Over voltage Overheat Ground fault Overload Eeprom error |
||||
Fan control | |||||
Weight | |||||
Options |
ELDI – А
ELDI – A variable frequency drives are designed for speed control of standard three phase AC motors with single phase power supply and
power range 0,55 kW to 2,2 kW
Parameter: | ELDI - A: | ||||||
---|---|---|---|---|---|---|---|
Motor power | 0.55kW 0.75kW 1.1kW 1.5kW 2.2kW |
||||||
Supply voltage and frequency | |||||||
Rated output voltage | |||||||
Rated output current | 3.0A 4.3A 5.9A 7.1A 10.1A |
||||||
Motor control methods | Version C | flux vector control |
|||||
Version C2 | flux vector control with feedback from tacho or encoder |
||||||
Degree of protection | |||||||
Output frequency | |||||||
Overload current capacity | |||||||
Acceleration / Deceleration time | |||||||
Frequency control | With keypad | ||||||
External signal | |||||||
potentiometer 2 ÷ 10kΩ |
|||||||
Start Stop Reverse | With keypad | button “Stop” |
|||||
External signal | |||||||
Inputs | Analog 4 ÷ 20mA Two analog 0 ÷ 10V Digital - “F/R” |
||||||
Relay outputs | |||||||
Programmable analog outputs | |||||||
Protections | Undervoltage Ground fault Overload Eeprom error Overvoltage Overheat |
||||||
Fan control | |||||||
Weight | 1.5kg 1.5kg 1.5kg 2.2kg 2.2kg |
||||||
Options | RS 232 (with additional TTL-RS converter) Remote control - with LCS display / without display (reversible / nonreversible) with LED display and keyboard by RS port |


ELDI – B
ELDI – B variable frequency drives are designed for speed control of standard three phase AC motors with three phase power supply and
power range 0,55 kW to 5,5 kW
Parameter: | ELDI - B: | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Motor power | 0.55kW 0.75kW 1.1kW 1.5kW 2.2kW 3.0kW 4.0kW 5.5kW |
|||||||||
Supply voltage and frequency | ||||||||||
Rated output voltage | ||||||||||
Rated output current | 2.3A 3.2A 4.2A 6.0A 7.6A 10.2A 12.5A |
|||||||||
Motor control methods | Version C | flux vector control |
||||||||
Version C2 | flux vector control with feedback from tacho or encoder |
|||||||||
Degree of protection | ||||||||||
Output frequency | ||||||||||
Overload current capacity | ||||||||||
Acceleration / Deceleration time | ||||||||||
Frequency control | With keypad | |||||||||
External signal | 4 ÷ 20mA (input impedance 250Ω) potentiometer 2 ÷ 10kΩ |
|||||||||
Start Stop Reverse | With keypad | button “Stop” Reverse - through “dtS” - F/R |
||||||||
External signal | Reverse - digital input “F/R” |
|||||||||
Inputs | Analog 4 ÷ 20mA Two analog 0 ÷ 10V; Digital - “F/R” |
|||||||||
Relay outputs | ||||||||||
Programmable analog outputs | ||||||||||
Protections | Under voltage Over voltage Overheat Ground fault Overload Eeprom error |
|||||||||
Fan control | ||||||||||
Weight | 1,5kg 1,5kg 2,2kg 2,2kg 2,6kg 3,4kg 3,4kg |
|||||||||
Options | RS 232 (with additional TTL-RS converter) Remote control - with LCS display / without display (reversible / nonreversible) with LED display and keyboard by RS port |
ELDI – DF
ELDI – DF variable frequency drives are designed for speed control of standard three phase AC motors with three phase power supply and
power range 7,5 kW to 11,0 kW
Parameter: | ELDI - DF: | ||||
---|---|---|---|---|---|
Motor power | 7.5kW 11kW |
||||
Supply voltage and frequency | 50/60Hz ±5% |
||||
Rated output voltage | 380 ÷ 400V 3~ (corresponds to the input voltage) | ||||
Rated output current | 16A 22A |
||||
Motor control methods | Version C | flux vector control |
|||
Version C2 | |||||
Degree of protection | |||||
Output frequency | |||||
Overload current capacity | |||||
Acceleration / Deceleration time | |||||
Frequency control | With keypad | ||||
External signal | |||||
Start Stop Reverse | With keypad | button “Stop” |
|||
External signal | |||||
Inputs | Analog 4 ÷ 20mA Two analog 0 ÷ 10V Digital - “F/R” |
||||
Relay outputs | (ready; speed reference reached) |
||||
Programmable analog outputs | (output frequency / motor current) |
||||
Protections | Undervoltage Overvoltage Overheat Ground fault Overload Eeprom error |
||||
Fan control | Detect heatsink temperature to start or stop the cooling fan | ||||
Weight | |||||
Options | (with additional TTL-RS converter) Remote control - with LCS display / without display (reversible / nonreversible) with LED display and keyboard by RS port |


ELDI / V – A
ELDI/V – A variable frequency drives are designed for vector control of standard three phase AC motors with single phase power supply and
power range 0,55 kW to 2,2 kW
Parameter: | ELDI / V - A: | |||
---|---|---|---|---|
Motor power | 1.1kW 1.5kW 2.2kW |
|||
Supply voltage and frequency | ||||
Rated output voltage | ||||
Rated output current | 5.9A 7.1A 10.1A |
|||
Motor control methods | Open loop U/F Closed Loop Vector control Sensorless Vector control |
|||
Speed control range | 1:1000 (Closed Loop Vector control) |
|||
Degree of protection | ||||
Output frequency | ||||
Output current overload capacity | ||||
Acceleration / Deceleration time | ||||
Controls | through external Analog signal by external potentiometer using Pulse Train input Operator Keypad settings |
|||
Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
||
Digital inputs | ||||
Serial interface | ||||
Inputs | Analog | |||
Digital | ||||
Outputs | Analog | |||
Digital | ||||
Relays | ||||
Compatible encoders and feedback interfaces | ||||
Protections | Under Voltage Over Voltage Over Heat Earth Fault Over Load (l2t) PG Fail, Disconnected Output Phase |
|||
Fieldbus Connectivity | RS 232 (optional) |
|||
Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
ELDI / V – B
ELDI/V – B variable frequency drives are designed for vector control of standard three phase AC motors with three phase power supply and
power range 0,55 kW to 5,5 kW
Parameter: | ELDI / V - B: | ||||||||
---|---|---|---|---|---|---|---|---|---|
Motor power | 0.5kW 0.7kW 1.1kW 1.5kW 2.2kW 3kW 4kW 5kW | ||||||||
Supply voltage and frequency | |||||||||
Rated output voltage | |||||||||
Rated output current | 2.0A 2.3A 3.2A 4.2A 6.0A 7.6A 10.0A 12.0A |
||||||||
Motor control methods | Open loop U/F. Closed Loop Vector control. Sensorless Vector control |
||||||||
Speed control range | 1:1000 (Closed Loop Vector control) |
||||||||
Degree of protection | |||||||||
Output frequency | |||||||||
Output current overload capacity | |||||||||
Acceleration / Deceleration time | |||||||||
Controls | through external Analog signal. by external potentiometer. using Pulse Train input Operator Keypad settings through Modbus RTU (RS485) |
||||||||
Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
|||||||
Digital inputs | |||||||||
Serial interface | |||||||||
Inputs | Analog | 0 ÷ 10V or 4 ÷ 20mA |
|||||||
Digital | |||||||||
Outputs | Analog | ||||||||
Digital | |||||||||
Relays | |||||||||
Compatible encoders and feedback interfaces | |||||||||
Protections | Over Voltage, Over Heat Earth Fault, Over Load (l2t) PG Fail Disconnected Output Phase |
||||||||
Fieldbus Connectivity | RS 232 (optional) |
||||||||
Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
||||||||


ELDI / V – DF
Parameter: | ELDI / V - DF: | ||
---|---|---|---|
Motor power | 11.0kW |
||
Supply voltage and frequency | |||
Rated output voltage | |||
Rated output current | 22A |
||
Motor control methods | |||
Speed control range | 1:1000 (Closed Loop Vector control) |
||
Degree of protection | |||
Output frequency | |||
Output current overload capacity | |||
Acceleration / Deceleration time | |||
Controls | through external Analog signal by external potentiometer; using Pulse Train input Operator Keypad settings through Modbus RTU (RS485) |
||
Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
|
Digital inputs | |||
Serial interface | |||
Inputs | Analog | 0 ÷ 10V or 4 ÷ 20mA |
|
Digital | |||
Outputs | Analog | ||
Digital | |||
Relays | |||
Compatible encoders and feedback interfaces | |||
Protections | Under Voltage Over Voltage Over Heat Earth Fault Over Load (l2t) PG Fail Disconnected Output Phase |
||
Fieldbus Connectivity | Modbus RTU RS 232 (optional) |
||
Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
ELDI / V – D
ELDI/V – D variable frequency drives are designed for vector control of standard three phase AC motors with three phase power supply and
power range 15,0 kW to 75,0 kW
Parameter: | ELDI / V - D: | |||||||
---|---|---|---|---|---|---|---|---|
Motor power | 15kW 18kW 22kW 30kW 37kW 45kW 55kW 75kW | |||||||
Supply voltage and frequency | ||||||||
Rated output voltage | ||||||||
Rated output current | 29A 36A 42A 62A 72A 85A 105A 138A |
|||||||
Motor control methods | Open loop U/F. Closed Loop Vector control. Sensorless Vector control |
|||||||
Speed control range | ||||||||
Degree of protection | ||||||||
Output frequency | ||||||||
Output current overload capacity | ||||||||
Acceleration / Deceleration time | ||||||||
Controls | through external Analog signal. by external potentiometer. using Pulse Train input Operator Keypad settings through Modbus RTU (RS485) |
|||||||
Start Stop Reverse | Operator keypad | Start / Stop / Reverse commands |
||||||
Digital inputs | ||||||||
Serial interface | ||||||||
Inputs | Analog | 0 ÷ 10V or 4 ÷ 20mA |
||||||
Digital | ||||||||
Outputs | Analog | |||||||
Digital | ||||||||
Relays | ||||||||
Compatible encoders and feedback interfaces | ||||||||
Protections | Over Voltage, Over Heat Earth Fault, Over Load (l2t) PG Fail, Disconnected Output Phase |
|||||||
Fieldbus Connectivity | RS 232 (optional) |
|||||||
Additional features and options | Position control Torque limit control PC software for configuration and maintenance |
|||||||